Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arq. bras. cardiol ; 113(2): 231-239, Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1019385

ABSTRACT

Abstract Background: Thoracic bioreactance (TB), a noninvasive method for the measurement of cardiac output (CO), shows good test-retest reliability in healthy adults examined under research and resting conditions. Objective: In this study, we evaluate the test-retest reliability of CO and cardiac power (CPO) output assessment during exercise assessed by TB in healthy adults under routine clinical conditions. Methods: 25 test persons performed a symptom-limited graded cycling test in an outpatient office on two different days separated by one week. Cardiorespiratory (power output, VO2peak) and hemodynamic parameters (heart rate, stroke volume, CO, mean arterial pressure, CPO) were measured at rest and continuously under exercise using a spiroergometric system and bioreactance cardiograph (NICOM, Cheetah Medical). Results: After 8 participants were excluded due to measurement errors (outliers), there was no systematic bias in all parameters under all conditions (effect size: 0.2-0.6). We found that all noninvasively measured CO showed acceptable test-retest-reliability (intraclass correlation coefficient: 0.59-0.98; typical error: 0.3-1.8). Moreover, peak CPO showed better reliability (intraclass correlation coefficient: 0.80-0.85; effect size: 0.9-1.1) then the TB CO, thanks only to the superior reliability of MAP (intraclass correlation coefficient: 0.59-0.98; effect size: 0.3-1.8). Conclusion: Our findings preclude the clinical use of TB in healthy subject population when outliers are not identified.


Resumo Fundamento: A biorreatância torácica (BT), um método não invasivo destinado à medição do débito cardíaco (DC), mostra boa confiabilidade teste-reteste em adultos saudáveis examinados em condições de pesquisa e repouso. Objetivo: No presente estudo, avaliamos a confiabilidade teste-reteste da avaliação do DC e trabalho cardíaco (TC) durante exercício, avaliado por BT em adultos saudáveis sob condições clínicas de rotina. Métodos: 25 indivíduos realizaram teste ergométrico gradual sintoma-limitante em ambiente ambulatorial em dois dias diferentes, com intervalo de uma semana. Parâmetros cardiorrespiratórios (trabalho cardíaco, VO2máx) e hemodinâmicos (frequência cardíaca, volume sistólico, DC, pressão arterial média, TC) foram medidos em repouso e continuamente sob exercício utilizando sistema espiroergométrico e cardiógrafo de biorreatância (NICOM, Cheetah Medical). Resultados: Após 8 participantes terem sido excluídos devido a erros de medição (outliers), não houve viés sistemático em nenhum dos parâmetros em todas as condições (tamanho do efeito: 0,2-0,6). Observamos que todos os débitos cardíacos medidos de forma não invasiva apresentaram níveis aceitáveis de confiabilidade teste-reteste (coeficiente de correlação intraclasse: 0,59-0,98; erro típico: 0,3-1,8). Além disso, TC máximo apresentou melhor confiabilidade (coeficiente de correlação intraclasse: 0,80-0,85; tamanho do efeito: 0,9-1,1), seguido do DC pela BT, graças apenas à confiabilidade superior da PAM (coeficiente de correlação intraclasse: 0,59-0,98; tamanho do efeito: 0,3-1,8). Conclusão: Nossos achados impedem o uso clínico da BT em indivíduos saudáveis quando outliers não forem identificados.


Subject(s)
Humans , Male , Female , Middle Aged , Cardiac Output/physiology , Exercise/physiology , Oxygen Consumption/physiology , Reference Values , Anaerobic Threshold/physiology , Prospective Studies , Reproducibility of Results , Exercise Test/methods , Hemodynamics/physiology
2.
Arq. bras. cardiol ; 109(5): 448-456, Nov. 2017. tab, graf
Article in English | LILACS | ID: biblio-887957

ABSTRACT

Abstract Background: Endostatin is a circulating endogenous angiogenesis inhibitor preventing neovascularization. Previous studies demonstrated the prognostic value of Endostatin among patients with heart failure with reduced ejection fraction (HFrEF). However, the role of Endostatin among patients with heart failure with preserved ejection fraction (HFpEF) remains unclear. Objective: This study aimed to investigate the association between serum Endostatin levels, natriuretic peptide levels and the severity of left ventricular diastolic dysfunction and the diagnosis of HFpEF. Methods: Endostatin serum concentrations were measured in 301 patients comprising 77 HFpEF patients, 169 patients with asymptomatic left ventricular diastolic dysfunction (ALVDD), and 55 controls with normal cardiac function. Results: Endostatin serum levels were significantly elevated in patients with HFpEF (median/interquartile range 179.0 [159-220]) and ALVDD (163.8 [145.4-191.3]) compared to controls (149.1 [130.6-176.9]), p < 0.001 and p = 0.004, respectively) and significant correlated with N-terminal pro B-type natriuretic peptide (NT-proBNP). Conclusions: This hypothesis-generating pilot study gives first evidence that Endostatin correlates with the severity of diastolic dysfunction and may become a novel biomarker for HFpEF. We hypothesize a rise in Endostatin levels may reflect inhibition of adaptive angiogenesis and adverse cardiac remodeling.


Resumo Fundamentos: A Endostatina é um inibidor circulante endógeno da angiogênese que previne a neovascularização. Estudos anteriores demonstraram o valor prognóstico da Endostatina em pacientes com insuficiência cardíaca com fracção de ejeção reduzida (ICFEr). No entanto, o papel da Endostatina entre os pacientes com insuficiência cardíaca com fração de ejeção preservada (ICFEp) permanece incerto. Objetivo: Investigar a associação entre os níveis séricos de Endostatina, níveis de peptídeos natriuréticos e a gravidade de disfunção ventricular esquerda e diastólica e o diagnóstico de ICFEp. Métodos: Mediu-se a concentração sérica de Endostatina em 301 pacientes, compreendendo 77 pacientes com ICFEp, 169 pacientes com disfunção ventricular esquerda assintomática diastólica (DVEAD) e 55 controles com a função cardíaca normal. Resultados: Os níveis de Endostatina no soro foram significativamente elevados em pacientes com ICFEp (mediana / intervalo interquartil 179,0 [159-220]) e DVEAD (163,8 [145,4-191,3]) em comparação com os controles (149,1 [130,6-176,9]), p < 0,001 e p = 0,004, respectivamente) e correlação significativa com o terminal do pro-peptídeo natriurético tipo B (NT-proBNP). Conclusões: Este estudo piloto gerador de hipótese fornece a primeira evidência de que a Endostatina se correlaciona com a gravidade da disfunção diastólica e pode tornar-se um novo biomarcador para ICFEp. Nossa hipótese é de que um aumento nos níveis de Endostatina pode refletir inibição da angiogênese adaptativa e remodelação cardíaca adversa.


Subject(s)
Humans , Male , Middle Aged , Aged , Stroke Volume/physiology , Ventricular Dysfunction, Left/blood , Endostatins/blood , Heart Failure/blood , Prognosis , Severity of Illness Index , Echocardiography , Biomarkers/blood , Case-Control Studies , Ventricular Dysfunction, Left/physiopathology , Endostatins/physiology , Heart Failure/physiopathology
3.
Arq. bras. cardiol ; 98(3): 234-242, mar. 2012. ilus, tab
Article in Portuguese | LILACS | ID: lil-622521

ABSTRACT

FUNDAMENTO: A ecocardiografia transtorácica (ETT) é rotineiramente utilizada para calcular a área da valva aórtica (AVA) pela equação de continuidade (EC). No entanto, a medida exata das vias de saída do ventrículo esquerdo (VSVE) pode ser difícil e a aceleração do fluxo no VSVE pode levar a erro de cálculo da AVA. OBJETIVO: O objetivo do nosso estudo foi comparar as medições da AVA por ETT padrão, ressonância magnética cardíaca (RM) e uma abordagem híbrida que combina as duas técnicas. MÉTODOS: A AVA foi calculada em 38 pacientes (idade 73 ± 9 anos) com a ETT padrão, planimetria cine-RM e uma abordagem híbrida: Método híbrido 1: a medição da VSVE derivada pelo ETT no numerador CE foi substituída pela avaliação de ressonância magnética da VSVE e a AVA foi calculada: (VSVE RM/*VSVE-VTI ETT)/transaórtico-VTI ETT; Método 2: Substituímos o VS no numerador pelo VS derivado pela RM e calculamos a AVA = VS RM/transaórtico-VTI ETT. RESULTADOS: Amédia de AVAobtida pela ETTfoi 0,86 cm² ± 0,23 cm² e 0,83 cm² ± 0,3 cm² pela RM-planimetria, respectivamente. A diferença média absoluta da AVA foi de 0,03 cm² para a RM versus planimetria-ressonância magnética. A AVA calculada com o método 1 e o método 2 foi de 1,23 cm² ± 0,4 cm² e 0,92cm² ± 0,32 cm², respectivamente. A diferença média absoluta entre a ETT e os métodos 1 e 2 foi de 0,37 cm² e 0,06 cm², respectivamente (p < 0,001). CONCLUSÃO: A RM-planimetria da AVA e o método híbrido 2 são precisos e demonstraram boa consistência com as medições padrão obtidas pela ETT. Portanto, o método híbrido 2 é uma alternativa razoável na eventualidade de janelas acústicas ruins ou em caso de acelerações de fluxo VSVE que limitem a precisão da ETT, particularmente em pacientes com alto risco de um estudo hemodinâmico invasivo.


BACKGROUND: Transthoracic echocardiography (TTE) is routinely used to calculate aortic valve area (AVA) by continuity equation (CE). However, accurate measurement of the left ventricular outflow tract (LVOT) can be difficult and flow acceleration in the LVOT may lead to miscalculation of the AVA. OBJECTIVE: The aim of our study was to compare AVA measurements by standard TTE, cardiac magnetic resonance imaging (MRI) and a hybrid approach combining both techniques. METHODS: AVA was calculated in 38 patients (age 73±9 years) with standard TTE, cine-MRI planimetry and a hybrid approach: Hybrid Method 1: TTE-derived LVOT measurement in the CE numerator was replaced by the MRI assessment of the LVOT and AVA was calculated: (LVOT MRI/*LVOT-VTI TTE)/transaortic-VTI TTE. Method 2: We replaced the SV in the numerator by the MRI-derived SV and calculated AVA = SV MRI/ transaortic-VTI TTE. RESULTS: Mean AVA derived by TTE was 0.86 cm²±0.23 cm² and 0.83 cm²±0.3 cm² by MRI- planimetry, respectively. The mean absolute difference in AVA was 0.03cm² for TTE vs. MRI planimetry. AVA calculated with method 1 and method 2 was 1.23 cm²±0.4cm² and 0.92cm²±0.32cm², respectively. The mean absolute difference between TTE and method 1 and method 2 was 0.37cm² and 0.06cm², respectively (p<0.001). CONCLUSION: MRI-planimetry of AVA and hybrid method 2 are accurate and showed a good agreement with standard TTE measurements. Therefore, hybrid method 1 is a reasonable alternative if poor acoustic windows or LVOT flow accelerations limit the accuracy of TTE, particularly in patients at high risk for an invasive hemodynamic study.


FUNDAMENTO: La ecocardiografía transtorácica (ETT) es habitualmente utilizada para calcular el área de la válvula aórtica (AVA) por la ecuación de continuidad (EC). Mientras tanto, la medida exacta de las vías de salida del ventrículo izquierdo (VSVI) puede ser difícil y la aceleración del flujo en el VSVI puede llevar a error de cálculo del AVA. OBJETIVO: El objetivo del nuestro estudio fue comparar las mediciones del AVA por ETT estándar, resonancia magnética cardíaca (RM) y un abordaje híbrido que combina las dos técnicas. MÉTODOS: AEI AVA fue calculada en 38 pacientes (edad 73 ± 9 años) con la ETT estándar, planimetría cine-RM y un abordaje híbrido: Método híbrido 1: la medición de la VSVI derivada por el ETT en el numerador CE fue substituida por la evaluación de resonancia magnética de la VSVI y el AVA fue calculada: (VSVI RM/*VSVI-VTI ETT)/transaórtico-VTI ETT; Método 2: Substituimos el VS en el numerador por el VS derivado por la RM y calculamos el AVA = VS RM/transaórtico-VTI ETT. RESULTADOS: La media de AVA obtenida por la ETT fue 0,86 cm² ± 0,23 cm2 y 0,83 cm² ± 0,3 cm² por la RM-planimetría, respectivamente. La diferencia media absoluta del AVA fue de 0,03 cm² para la RM versus planimetría-resonancia magnética. El AVA calculada con el método 1 y el método 2 fue de 1,23 cm² ± 0,4 cm² y 0,92cm² ± 0,32 cm², respectivamente. La diferencia media absoluta entre la ETT y los métodos 1 y 2 fue de 0,37 cm² y 0,06 cm², respectivamente (p < 0,001). CONCLUSION: La RM-planimetría del AVA y el método híbrido 2 son precisos y demostraron buena consistencia con las mediciones estándar obtenidas por la ETT. Por lo tanto, el método híbrido 2 es una alternativa razonable en la eventualidad de ventanas acústicas malas o en caso de aceleraciones de flujo VSVI que limiten la precisión de la ETT, particularmente en pacientes con alto riesgo de un estudio hemodinámico invasivo.


Subject(s)
Aged , Female , Humans , Male , Aortic Valve Stenosis/diagnosis , Echocardiography, Doppler/methods , Magnetic Resonance Imaging, Cine/methods , Analysis of Variance , Aortic Valve Stenosis/pathology , Aortic Valve/pathology , Aortic Valve , Blood Flow Velocity/physiology , Blood Pressure/physiology , Image Interpretation, Computer-Assisted/methods , Image Interpretation, Computer-Assisted/standards , Statistics, Nonparametric
4.
Arq. bras. cardiol ; 97(1): 65-75, jul. 2011. graf, tab
Article in Portuguese | LILACS | ID: lil-597661

ABSTRACT

FUNDAMENTO: O fator de diferenciação de crescimento-15 ou GDF-15, uma citocina de resposta ao estresse relacionada ao fator transformador de crescimento beta (TGF-ß), está elevado e independentemente relacionado à prognóstico adverso na insuficiência cardíaca sistólica. OBJETIVO: O objetivo do presente estudo é investigar os níveis plasmáticos de GDF-15 em pacientes com disfunção diastólica pré-clínica ou insuficiência cardíaca com fração de ejeção normal (ICFEN). MÉTODOS: Avaliamos 119 pacientes com fração de ejeção (FE) normal, encaminhados à angiografia coronariana eletiva, dos quais 75 (63 por cento) tinham doença arterial coronariana (DAC). Os indivíduos foram classificados como tendo disfunção diastólica ventricular esquerda leve (DDVE grau I, n = 61), ICFEN (DDVE grau II ou III, n = 38) ou função diastólica normal (controles, n = 20). Em um subgrupo de 20 indivíduos, alterações no débito cardíaco (DC) foram medidas através de reinalação de gás inerte (Innocor®) em resposta a um teste hemodinâmico ortostático. RESULTADOS: Os níveis de GDF-15 na ICFEN [mediana 1,08, variação interquartil (0,88-1,30) ng/ml] eram significantemente mais altos do que nos controles [0,60 (0,50-0,71) ng/ml, p = 0,003] e em pacientes com DDVE grau I [0,78 (0,62-1,04) ng/ml, p < 0.001]. Além disso, os níveis de GDF-15 estavam significantemente elevados em pacientes com DDVE grau I, em comparação aos controles (p = 0,003). Adicionalmente, GDF-15 estava correlacionado com os marcadores ecocardiográficos de disfunção diastólica e estava correlacionado com a magnitude da resposta do CO à alteração na posição do corpo de ereta para supina (r = -0,67, p = 0,005). CONCLUSÃO: Os níveis de GDF-15 estão elevados em indivíduos com ICFEN e podem diferenciar função diastólica normal de DDVE. Além disso, os níveis de GDF-15 estão associados com uma redução na resposta do DC no teste hemodinâmico ortostático.


BACKGROUND: Growth differentiation factor-15 (GDF-15), a stress-responsive transforming growth factor-ß-related cytokine, is elevated and independently related to an adverse prognosis in systolic heart failure. OBJECTIVE: This study aimed to investigate plasma levels of GDF-15 in patients with preclinical diastolic dysfunction or heart failure with normal ejection fraction (HFnEF). METHODS: We evaluated 119 patients with normal ejection fraction referred for an elective coronary angiography, 75 (63 percent) of whom had coronary artery disease. Subjects were classified as having either mild left ventricular diastolic dysfunction (LVDD grade I, n = 61), HFnEF (LVDD grade II or III, n = 38) or normal diastolic function (controls, n = 20). In a subgroup of 20 subjects, changes in cardiac output (CO) were measured by inert gas rebreathing (InnocorTM) in response to an orthostatic hemodynamic test. RESULTS: Growth differentiation factor-15 levels in HFnEF [median 1.08, interquartile range (0.88-1.30) ng/ml] were significantly higher than in controls [0.60 (0.50-0.71) ng/ml, p = 0.003] and in patients with LVDD grade I [0.78 (0.62-1.04) ng/ml, p < 0.001]. In addition, GDF-15 was significantly elevated in patients with LVDD grade I compared to controls (p = 0.003). Furthermore, GDF-15 was correlated with echocardiographic markers of diastolic dysfunction and was correlated with the magnitude of CO response to the change in body position from standing to supine (r = -0.67, p = 0.005). CONCLUSION: Growth differentiation factor-15 levels are elevated in subjects with HFnEF and can differentiate normal diastolic function from asymptomatic LVDD. In addition, GDF-15 is associated with a reduced cardiac output response in the orthostatic hemodynamic test.


FUNDAMENTO: El factor de diferenciación de crecimiento-15 o GDF-15, una citocina de respuesta al estrés relacionada con el factor transformador de crecimiento beta (TGF-ß), es elevado y está independientemente relacionado con el pronóstico adverso en la insuficiencia cardíaca sistólica. OBJETIVO: El objetivo del presente estudio es investigar los niveles plasmáticos de GDF-15 en pacientes con disfunción diastólica preclínica o insuficiencia cardíaca con fracción de eyección normal (ICFEN). MÉTODOS: Evaluamos a 119 pacientes con fracción de eyección (FE) normal, derivados a angiografía coronaria electiva, de los cuales 75 (63 por ciento), tenían enfermedad arterial coronaria (EAC). Los individuos fueron clasificados como teniendo una disfunción diastólica ventricular izquierda leve (DDVI grado I, n = 61), ICFEN (DDVI grado II o III, n = 38), o función diastólica normal (controles, n = 20). En un subgrupo de 20 individuos, las alteraciones en el débito cardíaco (DC), se midieron a través de una nueva inhalación de gas inerte (Innocor®) en respuesta a un test hemodinámico ortostático. RESULTADOS: Los niveles de GDF-15 en la ICFEN [mediana 1,08, variación intercuartil (0,88-1,30) ng/ml], eran significantemente más altos que en los controles [0,60 (0,50-0,71) ng/ml, p = 0,003] y en los pacientes con DDVI grado I [0,78 (0,62-1,04) ng/ml, p < 0,001]. Además, los niveles de GDF-15 estaban significantemente elevados en los pacientes con DDVI grado I, en comparación con los controles (p = 0,003). Por añadidura, el GDF-15 estaba correlacionado con los marcadores ecocardiográficos de disfunción diastólica y con la magnitud de la respuesta del DC a la alteración en la posición del cuerpo variando de la posición erecta a la posición supina (r = -0,67, p = 0,005). CONCLUSIÓN: Los niveles de GDF-15 están elevados en individuos con ICFEN y pueden diferenciar una función diastólica normal de DDVI. Además, los niveles de GDF-15 están asociados con una reducción en la respuesta del DC en el test hemodinámico ortostático.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , /blood , Heart Failure, Systolic/diagnosis , Stroke Volume/physiology , Biomarkers/blood , Echocardiography , Glucose Tolerance Test , Heart Failure, Systolic/physiopathology , Hemodynamics/physiology , Reference Values , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL